System Types in Feedback Control with Saturating Actuators

Research output: Contribution to journalConference articlepeer-review

Abstract

This Technical Note extends the classical notion of system type to feedback control with saturating actuators. For step, ramp, and parabolic inputs, it defines the so-called trackable domains and evaluates steady state errors. It shows that, unlike the linear case, the role of the poles at the origin of the plant and the controller are different and, on this basis, extends the notion of system type. Results obtained are useful for selecting controllers and actuators to ensure desired trackable domains and steady state errors.

Original languageEnglish
Pages (from-to)4651-4656
Number of pages6
JournalProceedings of the American Control Conference
Volume6
StatePublished - 2003
Event2003 American Control Conference - Denver, CO, United States
Duration: 4 Jun 20036 Jun 2003