TY - JOUR
T1 - Real-time monitoring of HIFU treatment using pulse inversion
AU - Song, Jae Hee
AU - Yoo, Yangmo
AU - Song, Tai Kyong
AU - Chang, Jin Ho
PY - 2013/8/7
Y1 - 2013/8/7
N2 - Ultrasound (US) imaging is widely used for the real-time guidance of high-intensity focused ultrasound (HIFU) treatment at a relatively low cost. However, ultrasound image guided HIFU (USgHIFU) is limited in the real-time monitoring of HIFU treatment due to the large amplitude HIFU signals received by the US imaging transducer. The amplitude of the HIFU scattered signal is generally much higher than the amplitude of the pulse-echo signal received by the imaging transducer. This creates an interference pattern obscuring the image of the tissue. As such, it is difficult to monitor lesion location. This paper proposes a real-time monitoring method to be performed concurrently with the HIFU insonation, but without HIFU interference, which allows for the improvement of treatment accuracy and safety in USgHIFU. The proposed method utilizes the physical properties of pulse inversion which is capable of removing the fundamental and odd harmonic components of the HIFU interference. Therefore, it is possible to secure the desired spectral bandwidth used to construct US images for HIFU treatment monitoring. The performance of the proposed method was evaluated through experiments with both a bovine serum albumin phantom and a chicken breast. The results demonstrated that the proposed method is capable of providing interference-free US images, thus successfully allowing for US imaging during HIFU treatment.
AB - Ultrasound (US) imaging is widely used for the real-time guidance of high-intensity focused ultrasound (HIFU) treatment at a relatively low cost. However, ultrasound image guided HIFU (USgHIFU) is limited in the real-time monitoring of HIFU treatment due to the large amplitude HIFU signals received by the US imaging transducer. The amplitude of the HIFU scattered signal is generally much higher than the amplitude of the pulse-echo signal received by the imaging transducer. This creates an interference pattern obscuring the image of the tissue. As such, it is difficult to monitor lesion location. This paper proposes a real-time monitoring method to be performed concurrently with the HIFU insonation, but without HIFU interference, which allows for the improvement of treatment accuracy and safety in USgHIFU. The proposed method utilizes the physical properties of pulse inversion which is capable of removing the fundamental and odd harmonic components of the HIFU interference. Therefore, it is possible to secure the desired spectral bandwidth used to construct US images for HIFU treatment monitoring. The performance of the proposed method was evaluated through experiments with both a bovine serum albumin phantom and a chicken breast. The results demonstrated that the proposed method is capable of providing interference-free US images, thus successfully allowing for US imaging during HIFU treatment.
UR - https://www.scopus.com/pages/publications/84880637370
U2 - 10.1088/0031-9155/58/15/5333
DO - 10.1088/0031-9155/58/15/5333
M3 - Article
C2 - 23863761
AN - SCOPUS:84880637370
SN - 0031-9155
VL - 58
SP - 5333
EP - 5350
JO - Physics in Medicine and Biology
JF - Physics in Medicine and Biology
IS - 15
ER -