N2 - This work presents the single-chip integration of a multi-frequency surface acoustic wave resonator (SAWR) based humidity sensor. Graphene oxide (GO), a humidity-sensing material, is integrated onto a confined sensing area of SAWR via electrospray deposition (ESD). The ESD method allows ng-resolution deposition of GO, optimizing the amount of sensing material. The proposed sensor consists of SWARs at three different resonant frequencies (180, 200 and 250 MHz) with a shared common sensing region, thus allowing direct analysis of sensor performances at different operating frequencies. Our findings reveal that the resonant frequency of the sensor impacts both measurement sensitivity and stability. A higher operating frequency ensures better sensitivity but suffers from a larger damping effect from absorbed water molecules. The maximum measurement sensitivity of 17.4 ppm/RH% is achieved with low drift. In addition, the developed sensor exhibits improved stability and sensitivity by as much as 150% and 75% in frequency shift and Quality factor (Q), respectively, by carefully selecting the operating frequencies at a given RH% range. Finally, the sensors are used for various hygienic applications, such as non-contact proximity detection and face mask inspection.
AB - This work presents the single-chip integration of a multi-frequency surface acoustic wave resonator (SAWR) based humidity sensor. Graphene oxide (GO), a humidity-sensing material, is integrated onto a confined sensing area of SAWR via electrospray deposition (ESD). The ESD method allows ng-resolution deposition of GO, optimizing the amount of sensing material. The proposed sensor consists of SWARs at three different resonant frequencies (180, 200 and 250 MHz) with a shared common sensing region, thus allowing direct analysis of sensor performances at different operating frequencies. Our findings reveal that the resonant frequency of the sensor impacts both measurement sensitivity and stability. A higher operating frequency ensures better sensitivity but suffers from a larger damping effect from absorbed water molecules. The maximum measurement sensitivity of 17.4 ppm/RH% is achieved with low drift. In addition, the developed sensor exhibits improved stability and sensitivity by as much as 150% and 75% in frequency shift and Quality factor (Q), respectively, by carefully selecting the operating frequencies at a given RH% range. Finally, the sensors are used for various hygienic applications, such as non-contact proximity detection and face mask inspection.
UR - http://www.scopus.com/inward/record.url?scp=85156102925&partnerID=8YFLogxK
U2 - 10.1038/s41598-023-34099-7
DO - 10.1038/s41598-023-34099-7
M3 - Article
AN - SCOPUS:85156102925
SN - 2045-2322
VL - 13
JO - Scientific Reports
JF - Scientific Reports
IS - 1
M1 - 6838
ER -