TY - JOUR
T1 - A paddling based locomotive mechanism for capsule endoscopes
AU - Park, Sukho
AU - Park, Hyunjun
AU - Park, Sungjin
AU - Kim, Byungkyu
PY - 2006/7
Y1 - 2006/7
N2 - Diagnosis and treatment using the conventional flexible endoscope in gastro-intestinal tract are very common since advanced and instrumented endoscopes allow diagnosis and treatment by introducing the human body through natural orifices. However, the operation of endoscope is very labor intensive work and gives patients some pains. As an alternative, therefore, the capsule endoscope is developed for the diagnosis of digestive organs. Although the capsule endoscope has conveniences for diagnosis, it is passively moved by the peristaltic waves of gastro-intestinal tract and thus has some limitations for doctor to get the image of the organ and to diagnose more thoroughly. As a solution of these problems, various locomotive mechanisms for capsule endoscopes are introduced. In our proposed mechanism, the capsule-type microrobot has synchronized multiple legs that are actuated by a linear actuator and two mobile cylinders inside of the capsule. For the feasibility test of the proposed microrobot, a series of in-vitro experiments using small intestine without incision were carried out. From the experimental results, our proposed microrobot can advance along the 3D curved and sloped path with the velocity of about 3.29-6.26 mm/sec and 35.1-66.7% of theoretical velocity. Finally, the proposed locomotive mechanism can be not only applicable to micro capsule endoscopes but also effective to advance inside of gastro-intestinal tract.
AB - Diagnosis and treatment using the conventional flexible endoscope in gastro-intestinal tract are very common since advanced and instrumented endoscopes allow diagnosis and treatment by introducing the human body through natural orifices. However, the operation of endoscope is very labor intensive work and gives patients some pains. As an alternative, therefore, the capsule endoscope is developed for the diagnosis of digestive organs. Although the capsule endoscope has conveniences for diagnosis, it is passively moved by the peristaltic waves of gastro-intestinal tract and thus has some limitations for doctor to get the image of the organ and to diagnose more thoroughly. As a solution of these problems, various locomotive mechanisms for capsule endoscopes are introduced. In our proposed mechanism, the capsule-type microrobot has synchronized multiple legs that are actuated by a linear actuator and two mobile cylinders inside of the capsule. For the feasibility test of the proposed microrobot, a series of in-vitro experiments using small intestine without incision were carried out. From the experimental results, our proposed microrobot can advance along the 3D curved and sloped path with the velocity of about 3.29-6.26 mm/sec and 35.1-66.7% of theoretical velocity. Finally, the proposed locomotive mechanism can be not only applicable to micro capsule endoscopes but also effective to advance inside of gastro-intestinal tract.
KW - Capsule Endoscope
KW - Locomotive Capsule
KW - Microrobot
KW - Multi-Legged Locomotion
UR - https://www.scopus.com/pages/publications/33748325658
U2 - 10.1007/BF02916000
DO - 10.1007/BF02916000
M3 - Article
AN - SCOPUS:33748325658
SN - 1738-494X
VL - 20
SP - 1012
EP - 1018
JO - Journal of Mechanical Science and Technology
JF - Journal of Mechanical Science and Technology
IS - 7
ER -