TY - GEN
T1 - A new high-definition zoom method based on compounded direct pixel beamforming for medical ultrasound imaging
T2 - Medical Imaging 2013: Ultrasonic Imaging, Tomography, and Therapy
AU - Yoon, Sungsoo
AU - Lee, Jongpil
AU - Chang, Jin Ho
AU - Song, Tai Kyong
AU - Yoo, Yangmo
PY - 2013
Y1 - 2013
N2 - Conventional ultrasound imaging based on scan conversion suffers from blurring artifacts caused by interpolation[1]. Especially, when zooming an image for enlarging lesions during scan conversion (i.e., read-zoom), this blurring artifact becomes severe. To reduce blurring artifacts, a write-zoom method was previously proposed. However, it still presents blurring artifacts and lowers the frame rate due to increased line density. In this paper, a new high definition zoom method based on compounded direct pixel beamforming (CDPB) capable enhancing the detail and boundary of lesions is presented. The performance of the proposed method was evaluated with phantom and in vivo experiments by measuring the information entropy contrast (IEC). The radio-frequency channel data were acquired by using a 3.5-MHz convex array transducer with the SonixTouch research platform (Ultrasonix Medical Corp., Vancouver, BC, Canada). The enlarged images using a new high-definition zoom method based on CDPB (i.e., HDZ-CDPB) with 128 transmit scanlines were reconstructed along with read- and write zoom (RZ and WZ) images based on scan conversion by using 128 and 256 transmit scanlines, respectively. From the phantom experiments, the IEC value with the proposed HDZ-CDPB method was enhanced by maximally 42% and 29% compared to the RZ and WZ methods, respectively. This preliminary results indicate that the proposed HDZ-CDPB method would be useful for generating a high definition ultrasound zoom image with improved image quality compared to the conventional scan conversion based methods (i.e., RZ and WZ) while achieving the high frame rate.
AB - Conventional ultrasound imaging based on scan conversion suffers from blurring artifacts caused by interpolation[1]. Especially, when zooming an image for enlarging lesions during scan conversion (i.e., read-zoom), this blurring artifact becomes severe. To reduce blurring artifacts, a write-zoom method was previously proposed. However, it still presents blurring artifacts and lowers the frame rate due to increased line density. In this paper, a new high definition zoom method based on compounded direct pixel beamforming (CDPB) capable enhancing the detail and boundary of lesions is presented. The performance of the proposed method was evaluated with phantom and in vivo experiments by measuring the information entropy contrast (IEC). The radio-frequency channel data were acquired by using a 3.5-MHz convex array transducer with the SonixTouch research platform (Ultrasonix Medical Corp., Vancouver, BC, Canada). The enlarged images using a new high-definition zoom method based on CDPB (i.e., HDZ-CDPB) with 128 transmit scanlines were reconstructed along with read- and write zoom (RZ and WZ) images based on scan conversion by using 128 and 256 transmit scanlines, respectively. From the phantom experiments, the IEC value with the proposed HDZ-CDPB method was enhanced by maximally 42% and 29% compared to the RZ and WZ methods, respectively. This preliminary results indicate that the proposed HDZ-CDPB method would be useful for generating a high definition ultrasound zoom image with improved image quality compared to the conventional scan conversion based methods (i.e., RZ and WZ) while achieving the high frame rate.
KW - Blurring artifacts
KW - Direct pixel beamforming
KW - Read zoom
KW - Scan conversion
KW - Write zoom
KW - Zoom image
UR - http://www.scopus.com/inward/record.url?scp=84878394033&partnerID=8YFLogxK
U2 - 10.1117/12.2003452
DO - 10.1117/12.2003452
M3 - Conference contribution
AN - SCOPUS:84878394033
SN - 9780819494498
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2013
Y2 - 12 February 2013 through 14 February 2013
ER -